Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support
           
TTC 2740 6 cores, 32-bit, 300 MHz Up to 62 inputs (analog, digital, timer, SENT) 68 outputs (40 x PWM with current feedback) 8 x CAN FD
1 x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-T1
2 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d ISO 25119 AgPL d SRL2
ISO 26262 ASIL C ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2785 6 cores, 32-bit, 300 MHz Up to 62 inputs (analog, digital, timer, SENT) 68 outputs (40 x PWM with current feedback) 8 x CAN FD
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
2 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d ISO 25119 AgPL d SRL2
ISO 26262 ASIL C ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2310 3 cores, 32 bit, 300 MHz Up to 20 inputs (analog, digital, timer, SENT) 36 outputs (18 x PWM with current feedback) 4 x CAN FD
1x CAN ISOBUS
1 x CAN (wake-up capable)
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2380 3 cores, 32 bit, 300 MHz Up to 20 inputs (analog, digital, timer, SENT) 40 outputs (26 x PWM with current feedback) 4 x CAN FD
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-T1
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2385 3 cores, 32 bit, 300 MHz Up to 20 inputs (analog, digital, timer, SENT) 40 outputs (26 x PWM with current feedback) 4 x CAN FD
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2390 6 cores, 32-bit, 300 MHz Up to 20 inputs (analog, digital, timer, SENT) 40 outputs (26 x PWM with current feedback) 4 x CAN FD
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 2038 2 cores, 32 bit, 300 MHz Up to 16 inputs (analog, digital, timer, SENT) 16 outputs (10 x PWM with current feedback) 2 x CAN FD 
1x CAN ISOBUS 
1 x CAN (wake-up capable) 
1 x LIN
IEC 61508 SIL2 
EN ISO 13849 PL d 
ISO 25119 AgPL d SRL2 
ISO 26262 ASIL C 
ISO 19014 MPL d
C programming, 
CODESYS** Safety SIL 2 including support for CANopen Safey Master
TTC 590 32-bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration
TTC 580 32-bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
TTC 540 32-bit,
180 MHz
52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)
4 x CAN EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
TTC 510 32-bit,
180 MHz
44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)
3 x CAN
1x LIN
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
TTC 508 32-bit,
180 MHz
44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)
2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
C programming
TTC 94 16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
4 x CAN,
1 x LIN,
1 x RS 232
EN ISO 13849 PL d* CODESYS,
C programming
TTC 60 16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
2 x CAN,
1 x LIN,
1 x RS 232
  CODESYS
TTC 32S 16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN EN ISO 13849 PL d C programming
TTC 32 16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN   CODESYS
C programming
TTC 30S 16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN EN ISO 13849 PL c C programming
TTC 30 16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN   C programming

* available for C-programming only; ** upcoming