Sorry, you need to enable JavaScript to visit this website.

TTC 60’s compact, automotive-style housing withstands extreme conditions such as humidity, vibrations, temperature changes and mechanical load. Furthermore, the TTC 60 has the "International Protection Rating" IP 67 according to the international standard IEC 60529.

The TTC 60 has 512 kB external RAM and eight analog inputs that can be configured for different voltages in the range of 0-30V. A daughter board makes it possible to add customer specific resources.

Overview ECUs

Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support

TTC 2310

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)

36 outputs

4 x CAN

1 x CAN ISOBUS

1 x CAN (wake-up capable)

1 x LIN

IEC 61508 SIL2

EN ISO 13849 PL d

ISO 25119 AgPL d SRL2

ISO 26262 ASIL C

ISO 19014 MPL d

C programming,

CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2380

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)

40 outputs

4 x CAN

1 x CAN ISOBUS

1 x CAN wake-up capable)

2 x 100BASE-T1

1 x LIN

IEC 61508 SIL2

EN ISO 13849 PL d

ISO 25119 AgPL d SRL2

ISO 26262 ASIL C

ISO 19014 MPL d

C programming,

CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2385

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)

40 outputs

4 x CAN

1 x CAN ISOBUS

1 x CAN (wake-up capable)

2 x 100BASE-TX

1 x LIN

IEC 61508 SIL2

EN ISO 13849 PL d

ISO 25119 AgPL d SRL2

ISO 26262 ASIL C

ISO 19014 MPL d

C programming,

CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2390

6 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)

40 outputs

4 x CAN

1 x CAN ISOBUS

1 x CAN (wake-up capable)

2 x 100BASE-TX

1 x LIN

IEC 61508 SIL2

EN ISO 13849 PL d

ISO 25119 AgPL d SRL2

ISO 26262 ASIL C

ISO 19014 MPL d

C programming,

CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 590

32 bit,

180 MHz

36 inputs (analog, digital, timer)

60 outputs (36 x PWM with current feedback)

6 x CAN,

1x CAN ISOBUS,

1 x BroadR-Reach®,

1 x LIN,

1 x RS-232

EN 61508 SIL 2 +

EN ISO 13849 PL d +

ISO 25119 AgPL d* +

ISO 26262 ASIL C*

CODESYS Safety SIL 2,

C programming,

SAFERTOS® integration

TTC 580

32 bit,

180 MHz

36 inputs (analog, digital, timer)

60 outputs (36 x PWM with current feedback)

7 x CAN,

1 x Ethernet,

1 x LIN,

1 x RS-232

EN 61508 SIL 2 +

EN ISO 13849 PL d +

ISO 25119 AgPL d* +

ISO 26262 ASIL C*

CODESYS Safety SIL 2,

C programming,

SAFERTOS integration

TTC 540

32 bit,

180 MHz

52 inputs (analog, digital, timer)

44 outputs (28 x PWM with current feedback)

4 x CAN

EN 61508 SIL 2 +

EN ISO 13849 PL d +

ISO 25119 AgPL d* +

ISO 26262 ASIL C*

CODESYS Safety SIL 2,

C programming,

SAFERTOS integration

TTC 510

32 bit,

180 MHz

44 inputs (analog, digital, timer)

40 outputs (16 x PWM with current feedback)

3 x CAN

1x LIN

EN 61508 SIL 2 +

EN ISO 13849 PL d +

ISO 25119 AgPL d* +

ISO 26262 ASIL C*

CODESYS Safety SIL 2,

C programming,

SAFERTOS integration

TTC 508

32 bit,

180 MHz

44 inputs (analog, digital, timer)

32 outputs (10 x PWM with current measurement)

2 x CAN

1x CAN ISOBUS

1 x BroadR-Reach®

EN 61508 SIL 2 +

EN ISO 13849 PL d +

ISO 25119 AgPL d* +

ISO 26262 ASIL C*

C programming

TTC 94

16/32 bit,

80 MHz

28 inputs (analog & digital),

20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,

1 x LIN,

1 x RS 232

EN ISO 13849 PL d*

CODESYS,

C programming

TTC 60

16/32 bit,

80 MHz

28 inputs (analog & digital),

20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,

1 x LIN,

1 x RS 232

 

CODESYS

TTC 32S

16/32 bit,

80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,

voltage, PVG and 8 x PWM,

6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

TTC 32

16/32 bit,

80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,

voltage, PVG and 8 x PWM,

6 with current feedback)

2 x CAN

 

CODESYS

C programming

TTC 30S

16/32 bit,

80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,

voltage, PVG and 8 x PWM,

6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

TTC 30

16/32 bit,

80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,

voltage, PVG and 8 x PWM,

6 with current feedback)

1 x CAN

 

C programming

* available for C‐programming only; ** upcoming

scroll to top